Effect of sample configuration on AMTEC electrode/electrolyte characteristics measurements in a sodium exposure test cell
Overview
Identity
Additional Document Info
Other
View All
Overview
abstract
An experimental investigation was conducted to determine the effect of sample configuration on the alkali metal thermal-to-electric converter (AMTEC) electrode/electrolyte characteristics measurements in a sodium exposure test cell. Two electrode/electrolyte configurations (tube and disk) were tested to determine if there was a difference in the characteristics determined from the measurements. It was demonstrated that the configuration of the sample had little effect (15%) on the measurements at typical AMTEC operating temperatures. Electrochemical impedance spectroscopy and controlled potential current-voltage curve techniques were used to determine these characteristics.