Effect of different surface treatments on the retention force of additively manufactured interim implant-supported crowns. Academic Article uri icon

abstract

  • PURPOSE: To compare the effect of different pre-cementation surface treatments and bonding protocols on the retention force of additively manufactured (AM) implant-supported interim crowns. MATERIAL AND METHODS: A total of 50 AM interim crowns (Temporary CB resin) were cemented on implant abutments. Five groups (n = 10) were established based on the different surface pre-treatments performed in the intaglio surface of the specimens: no surface pre-treatment (Group C or control), air-abraded with 50-m aluminium oxide particles (Group AP), air-abraded with 50-m aluminium oxide particles followed by the application of silane (Group AMP), silane (Group MP), and air-abraded with 30m silica-coated aluminum oxide particles followed by the application of silane (Group CMP). Each specimen was cemented into an implant abutment using a composite resin cement (Rely X Unicem2). Afterward, the specimens underwent retention testing with a Universal Instron machine. Pull-off forces (N) and modes of failure were registered. Statistical analysis was performed using Mann-Whitney U tests with Bonferroni corrections for multiple tests ( = .05). RESULTS: The median retention force values were 233.27 79.28 N for Group Control, 398.59 68.59 N for Group MP, 303.21 116.80 N for Group AMP, 349.31 167.73 N for Group CMP, and 219.85 55.88 N for Group AP. The pull-off forces were significantly greater for Group MP, while the differences between the remaining groups were not statistically significant (P>0.05). Group AP showed the lowest retention force values among all the groups. Failure modes after the pull-off testing were predominantly adhesive and substrate failure of the AM interim material. CONCLUSIONS: The surface treatment of the intaglio AM crown tested significantly influenced the retention force values measured. Pre-treatment with an MDP-containing silane improved the retentive force values computed, whereas pre-treatment with 50-m Al2 O3 air-particle abrasion alone is not recommended prior to cementation on a titanium-based implant abutment. This article is protected by copyright. All rights reserved.

published proceedings

  • J Prosthodont

author list (cited authors)

  • Filokyprou, T., Kesterke, M. J., Liu, X., Cho, S., & Revilla-Len, M.

complete list of authors

  • Filokyprou, Thaleia||Kesterke, Matthew J||Liu, Xiaohua||Cho, Seok-Hwan||Revilla-León, Marta

publication date

  • October 2023

publisher