AN ELECTRICAL-CONDUCTIVITY METHOD FOR MEASURING THE EFFECTS OF ADDITIVES ON EFFECTIVE DIFFUSIVITIES IN PORTLAND-CEMENT PASTES
Academic Article
Overview
Identity
Additional Document Info
Other
View All
Overview
abstract
Effective diffusivities are important in describing corrosion and leaching of contaminants in cementitious systems. An electrical conductivity procedure has been used to measure the effective diffusivities of compounds in cementitious systems containing the additives fly ash, silica fume, sodium silicate and bentonite. Silica fume was the most effective additive in reducing the effective diffusivity, but fly ash was the most cost effective. Diffusivities that have been measured with techniques that rely on flux of a compound through the solid were generally lower than those measured with the electrical conductivity procedure. Porosity and bulk density are not well correlated with effective diffusivity in systems containing additives. 1992.