Improved partial inerting MIE test method for combustible dusts and its CFD validation Academic Article uri icon

abstract

  • 2018 The Minimum Ignition Energy (MIE) is an important dust hazard parameter that guides the elimination of possible ignition sources in solids handling facilities. Partial inerting is a dust explosion mitigation technique implemented in industries, where the dust cloud MIE is increased, reducing the risk of an accidental explosion. Previous work has shown that purging the MIE apparatus Hartmann tube before testing is essential for obtaining accurate MIE values, but have not discussed the importance of the effective purge time required. Through experimentation and CFD modeling, this study has attempted to refine the existing MIE testing standard for partial inerting applications by introducing purge time as an essential parameter. In this study, oxygen sensor measurements were conducted to determine that the purge time for the MIKE3 apparatus should be > 40 s. Additionally, an ANSYS Fluent CFD purging model was developed, which confirmed the experimentally determined purge time. Using this improved methodology, an accurate partial inerting data set was obtained for the combustible dusts Anthraquinone, Lycopodium clavatum and Calcium Stearate.

published proceedings

  • Process Safety and Environmental Protection

author list (cited authors)

  • Chaudhari, P., Ravi, B., Bagaria, P., & Mashuga, C.

citation count

  • 13

complete list of authors

  • Chaudhari, Purvali||Ravi, Bharatvaaj||Bagaria, Pranav||Mashuga, Chad

publication date

  • January 2019