Evaluation of the ASHRAE method for predicting capillary tube-suction line heat exchanger performance Conference Paper uri icon

abstract

  • The ASHRAE method of predicting capillary tube performance, including the effect of suction line heat exchange, was experimentally evaluated for R-12. Capillary tube-suction line heat exchangers are commonly used in household refrigerator application. For this study, performance test data were taken over a range of operating, conditions and heat exchanger geometries applicable to household refrigerators. Measured was flow rates and calculated effective subcooling values were compared to predictions using the appropriate ASHRAE design charts. Most mass flow rate data points fell within 5% of prediction, and all fell within 10% of prediction. Effective subcooling data were within 3 F(1.7 C) of prediction.

published proceedings

  • ASHRAE Transactions

author list (cited authors)

  • Bittle, R. R., Stephenson, W. R., & Pate, M. B.

complete list of authors

  • Bittle, RR||Stephenson, WR||Pate, MB

publication date

  • December 1995