Water quality impacts on sorbent efficacy for per- and polyfluoroalkyl substances treatment of groundwater Academic Article uri icon

abstract

  • AbstractPer and polyfluoroalkyl substances (PFAS) are a large group of synthetic compounds that have emerged as chemicals of concern in drinking water and groundwater. Typically, such waters are treated to remove PFAS by passing the water through a bed of sorbent material (e.g., activated carbonand anion exchange resins [AIX]). However, the efficacy of these sorbents varies depending on the types and concentrations of PFAS, in addition to water quality conditions such as organic matter content and conductivity (ionic strength). The choice of sorbent material to effectively treat PFAS in complex natural waters will, therefore, depend upon site water quality and PFAS conditions. To help inform these decisions, a series of evaluations using a rapid smallscale column test approach was conducted with two sorbent materials (a granulated activated carbon [GAC] and an AIX), individually and combined, under conditions where conductivity, pH, and organic carbon concentrations were varied in a semifactorial approach. Artificial groundwater batches were prepared to meet these test conditions and spiked with six PFAS compounds (perfluorobutane sulfonic acid [PFBS], perfluorobutanoic acid[PFBA], perfluorohexane sulfonic acid[PFHxS], perfluorohexanoic acid[PFHxA], perfluorooctane sulfonic acid[PFOS], and perfluorooctanoic acid[PFOA]), passed through small columns packed with ground sorbent material for 30,000 bed volumes of water for single sorbent treatments and 20,000 bed volumes for combined sorbent treatments, during which samples of effluent were captured and analyzed to quantify breakthrough of PFAS from the sorbent materials over time. AIX was found to be more effective than GAC at removing the tested perfluoroalkyl sulfonic acids (PFBS, PFHxS, andPFOS), but GAC was similarly or more effective than AIX at removing perfluorocarboxylic acids (PFBA, PFHxA, andPFOA) under high conductivity conditions. Overall, the efficacy of AIX at removing PFAS was more strongly impacted by organic carbon and conductivity than GAC, while pH had less of an effect on either sorbent's efficacy compared to the other test conditions.

published proceedings

  • REMEDIATION-THE JOURNAL OF ENVIRONMENTAL CLEANUP COSTS TECHNOLOGIES & TECHNIQUES

altmetric score

  • 0.75

author list (cited authors)

  • Hayman, N. T., Carilli, J. E., Liu, Y., Shields, M. R., Hsu, L., & George, R.

citation count

  • 0

complete list of authors

  • Hayman, Nicholas T||Carilli, Jessica E||Liu, Yina||Shields, Michael R||Hsu, Lewis||George, Robert

publication date

  • March 2023

publisher