Heat Transfer in Leading Edge, Triangular Shaped Cooling Channels with Angled Ribs under High Rotation Numbers Conference Paper uri icon

abstract

  • The gas turbine blade/vane internal cooling is achieved by circulating the compressed air through the cooling channels inside the turbine blade. Cooling channel geometries vary to fit the blade profile. This paper experimentally investigated the rotational effects on heat transfer in an equilateral triangular channel (Dh = 1.83cm). The triangular shaped channel is applicable to the leading edge of the gas turbine blade. 45 angled ribs are put on the leading and trailing surfaces of the test section to enhance heat transfer. The rib pitch-to-height ratio (P/e) is 8 and the height-to-hydraulic diameter ratio (e/Dh) is 0.087. Effect of the angled ribs under high rotation numbers and buoyancy parameters are also presented. Results show that due to the radially outward flow, heat transfer is enhanced with rotation on the trailing surface. By varying the Reynolds numbers (1000040000) and the rotational speeds (0400 rpm), the rotation number and buoyancy parameter reached in this study are 00.58 and 01.9, respectively. The higher rotation number and buoyancy parameter have been correlated very well to predict the rotational heat transfer in the equilateral triangular channel.

name of conference

  • Volume 4: Heat Transfer, Parts A and B

published proceedings

  • PROCEEDINGS OF THE ASME TURBO EXPO 2008, VOL 4, PTS A AND B

author list (cited authors)

  • Liu, Y., Huh, M., Rhee, D., Han, J., & Moon, H.

citation count

  • 6

complete list of authors

  • Liu, Yao-Hsien||Huh, Michael||Rhee, Dong-Ho||Han, Je-Chin||Moon, Hee-Koo

publication date

  • January 2008