Detailed heat transfer coefficient distributions under an array of impinging jets with coolant extraction Academic Article uri icon

abstract

  • Jet impingement cooling is a high performance technique for heat transfer enhancement. Local heat transfer distributions are presented for an array of jets impinging on a target plate with a series of coolant extraction holes. The flow enters the pressure channel, impinges on the target plate and exits toward the sides and through the coolant extraction holes. The impingement plate has four rows of 12 jet holes and the target plate has three rows of 11 coolant extraction holes. The jet holes and the coolant extraction holes have the same diameters and are staggered such that the air impinging from the jet hole does not exit directly through the extraction hole. The detailed heat transfer coefficient distributions are measured using a transient technique and liquid crystal coating. Results are presented for a range of jet Reynolds numbers between 4000 and 20000. The effect of crossflow is also studied by changing the exit opening of the impingement channel to provide three different spent air exit directions. Heat transfer results for the target plate with coolant extraction are compared with those without coolant extraction at the same flow conditions.

published proceedings

  • American Society of Mechanical Engineers, Heat Transfer Division, (Publication) HTD

author list (cited authors)

  • Huang, Y., Ekkad, S. V., & Han, J. C.

complete list of authors

  • Huang, Y||Ekkad, SV||Han, JC

publication date

  • December 1996