Change in regional (somatic) near-infrared spectroscopy is not a useful indicator of clinically detectable low cardiac output in children after surgery for congenital heart defects. Academic Article uri icon

abstract

  • OBJECTIVE: Near-infrared spectroscopy correlation with low cardiac output has not been validated. Our objective was to determine role of splanchnic and/or renal oxygenation monitoring using near-infrared spectroscopy for detection of low cardiac output in children after surgery for congenital heart defects. DESIGN: Prospective observational study. SETTING: Pediatric intensive care unit of a tertiary care teaching hospital. PATIENTS: Children admitted to the pediatric intensive care unit after surgery for congenital heart defects. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We hypothesized that splanchnic and/or renal hypoxemia detected by near-infrared spectroscopy is a marker of low cardiac output after pediatric cardiac surgery. Patients admitted after cardiac surgery to the pediatric intensive care unit over a 10-month period underwent serial splanchnic and renal near-infrared spectroscopy measurements until extubation. Baseline near-infrared spectroscopy values were recorded in the first postoperative hour. A near-infrared spectroscopy event was a priori defined as 20% drop in splanchnic and/or renal oxygen saturation from baseline during any hour of the study. Low cardiac output was defined as metabolic acidosis (pH <7.25, lactate >2 mmol/L, or base excess -5), oliguria (urine output <1 mL/kg/hr), or escalation of inotropic support. Receiver operating characteristic analysis was performed using near-infrared spectroscopy event as a diagnostic test for low cardiac output. Twenty children were enrolled: median age was 5 months; median Risk Adjustment for Congenital Heart Surgery category was 3 (1-6); median bypass and cross-clamp times were 120 mins (45-300 mins) and 88 mins (17-157 mins), respectively. Thirty-one episodes of low cardiac output and 273 near-infrared spectroscopy events were observed in 17 patients. The sensitivity and specificity of a near-infrared spectroscopy event as an indicator of low cardiac output were 48% (30%-66%) and 67% (64%-70%), respectively. On receiver operating characteristic analysis, neither splanchnic nor renal near-infrared spectroscopy event had a significant area under the curve for prediction of low cardiac output (area under the curve: splanchnic 0.45 [95% confidence interval 0.30-0.60], renal 0.51 [95% confidence interval 0.37-0.65]). CONCLUSIONS: Splanchnic and/or renal hypoxemia as detected by near-infrared spectroscopy may not be an accurate indicator of low cardiac output after surgery for congenital heart defects.

published proceedings

  • Pediatr Crit Care Med

altmetric score

  • 0.5

author list (cited authors)

  • Bhalala, U. S., Nishisaki, A., McQueen, D., Bird, G. L., Morrison, W. E., Nadkarni, V. M., Nathan, M., & Starr, J. P.

citation count

  • 30

complete list of authors

  • Bhalala, Utpal S||Nishisaki, Akira||McQueen, Derrick||Bird, Geoffrey L||Morrison, Wynne E||Nadkarni, Vinay M||Nathan, Meena||Starr, Joanne P

publication date

  • September 2012