Gas Labyrinth Seals: Improved Prediction of Leakage in Gas Labyrinth Seals Using an Updated Kinetic Energy Carry-Over Coefficient Conference Paper uri icon

abstract

  • Abstract Though simple and fast, bulk-flow models (BFMs) for gas labyrinth seals (LSs) often predict the mass flow inaccurately. The BFM models rely on classical Neumanns equation model to characterize the flow through a labyrinth tooth. Presently, a CFD analysis quantifies the effects of tip clearance (Cr) and operating conditions on the prediction of LS mass flow, and then derives an updated kinetic energy carry-over coefficient (1i) to improve the accuracy of Neumanns leakage equation. 1i is a function of the seal tip clearance (Cr), the tooth pitch, and the total teeth number; but it does not depend on the seal supply or discharge pressures. The analysis selects a fourteen teeth on stator LS (Length/Diameter = L/D = 0.29) with clearance Cr = (1/733)D and operating at nominal supply (Pin) and discharge (Pout) pressures equal to 73 bar and 51 bar, respectively, and at a rotor speed of 12 krpm (surface speed = 138 m/s.). The CFD produces flow fields for LSs with a clearance varying from 80% to 200% of the nominal Cr, a gas supply pressure from 60 bar to 100 bar, and with various discharge pressures giving a pressure ratio (PR = Pout/Pin) ranging from 0.40 to 0.85. The numerous predictions deliver the mass flow as well as the bulk-flow velocities and cavity pressures within the seals. The kinetic energy carry-over coefficient (1i) increases with respect to the seal radial clearance (Cr). 1i shows a parabolic correlation with PR; at first 1i increases with a rise in PR from a low value; and then a further increase in PR leads to a decrease in 1i. The coefficient 1i is only sensitive to the pressure ratio and not to the magnitude of either the supply or discharge pressures. Lastly, for use with Neumanns leakage model, the CFD predictions produce an updated 1i, a function of the seal geometry and the PR condition. Integration of the new 1i correlation into a BFM code improves its accuracy to predict LS mass flow rate, a 19% difference against test data reduces to within 6%. A TOS LS tested by Ertas et al. (2012) serves to further validate the accuracy of the modified leakage model.

name of conference

  • Volume 10A: Structures and Dynamics

published proceedings

  • Volume 10A: Structures and Dynamics

author list (cited authors)

  • Wu, T., & San Andrs, L.

citation count

  • 0

complete list of authors

  • Wu, Tingcheng||San AndrĂ©s, Luis

publication date

  • September 2020