EXPERIMENTAL STUDY OF THE STATIC AND DYNAMIC CHARACTERISTICS OF A LONG (L/D=0.75) LABYRINTH ANNULAR SEAL OPERATING UNDER TWO-PHASE (LIQUID/GAS) CONDITIONS Conference Paper uri icon

abstract

  • This research documents the development of a 2-phase annular-seal stand (2PASS) in the Turbomachinery Laboratory at Texas A&M University to investigate the static and dynamic characteristics of annular seals operating under 2-phase flow conditions. The 2PASS is modified from an existing air-annular seal test stand. It uses either spargers or a specially designed mixer to make a 2-phase flow, comprised of air and silicone oil (PSF-5cSt). Smooth annular seals with (length L=57.785 mm and length-to-diameter ratio L/D=0.65) are tested in the centered position for three radial clearances (Cvr=0.140, 0.163, and 0.188 mm) with zero intentional pre-swirl. Due to the difficulties in making homogeneous mixtures over the gas-volume fraction (GVF) range from 10% to 92%, tests are performed at pure- and mainly-oil conditions (GVF=10%) and pure- and mainly-air conditions (92%=GVF=100%), respectively. Under pure- and mainly-oil conditions, tests are conducted at exit pressure Pve=6.9 bars, rotor speed ?=5, 7.5, 10, and 15 krpm, pressure drop PD=31, 37.9, and 48.3 bars, and inlet GVF=0%, 2%, 4%, 6%, 8%, and 10%. At pure- and mainly-air conditions, tests are performed at inlet pressure Pvi=62 bars, ?=10, 15, and 20 krpm, pressure ratio PR=0.57, 0.5, and 0.43, and inlet GVF=100%, 98%, 95%, and 92%. Leakage mass flow rate ??? and rotordynamic coefficients are measured, and the effects of changing inlet GVF, Cvr, PD (or PR), and ? are studied. Test results show that adding fine air bubbles into the oil flow does not significantly change ???, but remarkably influences the seals rotordynamic performance. Increasing inlet GVF from zero to 10% generally decreases direct stiffness K when Cr=0.163 and 0.140 mm, but increases K when PD=31 and 37.9 bars and Cr=0.188 mm. As K drops to a large enough negative value, the seal stators 1st natural frequency drops significantly, causing a sub-synchronous vibration (instability at the stators 1st damped natural frequency), preventing further tests. Increasing inlet GVF from zero to 10% has little effect on effective damping Cveff and does not change the seals stabilizing force when Cvr=0.188 mm, but generally increases Cveff and makes the seal more stabilizing when Cvr=0.163 and 0.140 mm. For all three clearances under pure- and mainly-air conditions, ??? drops slightly (by less than 6%) as inlet GVF decreases from 100% to 98%, and then increases (by about 45%) with further decreasing inlet GVF to 92%. The oil presence in the air stream significantly impacts the seals rotordynamic characteristics. Direct dynamic stiffness KvO is frequency dependent and generally increases as O increases, especially after injecting oil. As inlet GVF decreases from 100% to 92%, KO generally decreases except that it increases as inlet GVF decreases from 100% to 98% in the following circumstances: (1) cases with PR=0.43 and Cr=0.188 mm, and (2) the case with PR=0.43, ?=20 krpm, and Cr=0.163 mm. Decreasing the seals KO would decrease the critical speed of the rotor in a centrifugal compressor. As O increases, vCeff changes from negative (destabilizing) to positive (stabilizing) at Ovc (the cross-over frequency). Oc is of great interest to the system stability. Injecting oil into the air stream increases Ovc, making the seal less stabilizing. Increasing Cvr from 0.140 to 0.188 mm decreases Oc, making the seal more stabilizing. However, an immediate disadvantage is that ??? increases significantly (by about 58%) as Cr increases from 0.140 to 0.188 mm. A program developed by San Andrs based on a bulk-flow model and the Moody friction model with isothermal and homogeneous-mixture assumptions produces predictions to compare with test results. For all three clearances at pure- and mainly-oil conditions, the program reasonably predicts ??? and Cveff. For most cases, K predictions are not close to test results. In a centrifugal pump, the poor agreement in K leads to prediction inaccuracy in the rotors critical speed. For all three clearances at pure- and mainly-air conditions, the program adequately predicts v???. Predicted KvO values are close to test results only under pure-air conditions when PR=0.5 and 0.57. For all other test conditions, KvO predictions are larger than measured, and the difference decreases as O increases due to the frequency dependence of KvO. In a centrifugal compressor, this discrepancy would mean that the rotors critical speed would be lower than predicted. Oc predictions agree with measurements when inlet GVF=100% and 98%, but are larger than measured results (by more than 37.1%) when inlet GVF=95% and 92%. Therefore, when inlet GVF=95% and 92%, the seal is more stabilizing than predicted.

published proceedings

  • PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 7B

author list (cited authors)

  • Shrestha, H., Childs, D. W., Tran, D. L., & Zhang, M.

citation count

  • 5

complete list of authors

  • Shrestha, Had||Childs, Dara W||Tran, Dung L||Zhang, Min

publication date

  • September 2019