Experimental and numerical investigation of a scaled-up passive micromixer using fluorescence technique Academic Article uri icon

abstract

  • The present paper investigates experimentally and numerically a scaled-up micromixer that combines the mixing principles of focusing/diverging and flow split-and-recombine. The micromixer consists of two units called "cross" and "omega", which are similar to a zigzag structure. The total length is 199.5 mm with a depth of 3 mm. Fluorescence technique is used in the present study for local quantitative measurements of concentration. Two syringe pumps are used to supply the working fluids at two inlets. The testing range of Reynolds number is at 1 Re 50. The results of the experiment, obtained by fluorescence technique, are supported by the mixing visualization. The experimental results show that the mixing efficiency decreases at Re 10 and increases at Re 10. This is caused by the change in mixing mechanism from mass-diffusion domination to mass-convection domination. After five cells, the mixing efficiency reaches to 70% at Re = 50. The computational fluid dynamics is applied to assist in the understanding of fluid characteristics in channels. The simulation has a good agreement with the experiment. Based on the simulation results, vortices are observed in the channels at high Re, which could stretch and fold the fluids to enhance the effect of mass-convection on mixing. This design has the potential to be developed for micromixers with high flow rates. 2010 Springer-Verlag.

published proceedings

  • Experiments in Fluids

author list (cited authors)

  • Fan, Y., & Hassan, I.

citation count

  • 7

complete list of authors

  • Fan, YanFeng||Hassan, Ibrahim

publication date

  • September 2010