Performance Comparison of two Sensorless Control Methods for Standalone Doubly-Fed Induction Generator
Conference Paper
Overview
Research
Identity
Additional Document Info
Other
View All
Overview
abstract
2014 IEEE. This paper presents a comparison study and analysis of two sensorless methods for the detection of rotor position of the standalone doubly fed induction generator (DFIG). Although, there are available several sensorless control methods for DFIG, the paper deals with two popular methods. These methods are stator flux based model reference adaptive system (MRAS) observer and rotor position phase-locked-loop (PLL) method. The discussed sensorless control methods are designed and simulated in Matlab&Simulink. The performances of both sensorless control methods are analyzed with respect to standalone operation. Compared study of their performances under startup process and at different speed conditions is also presented.
name of conference
2014 16th International Power Electronics and Motion Control Conference and Exposition