MICROBIOLOGICAL EVALUATION OF GROUND BEEF CONTAINING MECHANICALLY DEBONED BEEF
Overview
Research
Identity
Additional Document Info
Other
View All
Overview
abstract
Ground beef chub packs containing 0, 5, 10, 15, 20, 25 or 30% mechanically deboned beef (MDB) were examined for aerobic plate counts (5C and 35C), coliforms, Escherichia coli, Staphylococcus aureus, Clostridium perfringens and salmonellae after storage at two temperatures for various times. Chub packs were stored at 1.1C for 0, 6, 12, 18 and 24 days and at 23.3C for 2, 4 and 6 months. Isolation of Salmonella enteritidis serotype rubislaw from the pure MDB used in product formulation and from two (1%) of the chub packs containing MDB indicated that a large number of commercial samples of MDB from various sources should be evaluated. However, the aerobic plate counts, coliform, E. coli, S. aureus and C. perfringens counts in the seven formulations indicated that the addition of MDB to ground beef at levels up to 30% would not affect microbiological safety or shelflife if the product were formulated and stored according to the procedures outlined in this study. Copyright 1978, Wiley Blackwell. All rights reserved