A method of bite force measurement in primates. Academic Article uri icon

abstract

  • A bite force transducer consisting of two differential strain beams with four strain gages in a full bridge configuration was modified for measuring occlusal forces in rhesus monkeys. A procedure of muscle stimulation (20-50 V, 60 Hz, and 0.8 ms duration) produced maximal unilateral masticatory muscle contraction when stimulating electrodes were placed in the masseter muscle. Tests of this procedure revealed reproducible results and a potential for use in studies of the force of isometric contraction of the masticatory muscles in normal and experimentally altered macaques and other primates.

published proceedings

  • J Biomech

altmetric score

  • 3

author list (cited authors)

  • Dechow, P. C., & Carlson, D. S.

citation count

  • 49

complete list of authors

  • Dechow, PC||Carlson, DS

publication date

  • January 1983