Electroplated electro-fluidic interconnects for chemical sensors11This work was completed at The Microfabrication Applications Laboratory at The Universityof Illinois at Chicago.
Academic Article
Overview
Identity
Additional Document Info
Other
View All
Overview
abstract
A wet chip electro-fluidic packaging technology based on electroplating is described. An electroplated gold seal provides the sensor's fluid connection to a silicon multi-chip module. A hermetic seal is obtained using the gold-silicon eutectic bond. The sensor's electrical connections to the multi-chip module are made by eutectic bonding electroplated gold-tin solder bumps on the sensor to gold pads on the substrate. The fluid and electrical connections are made simultaneously, and the process is compatible with the flip-chip bonding technique.