Existence of critical recovery and impacts of operational mode on potable water microfiltration
Academic Article
Overview
Identity
Additional Document Info
Other
View All
Overview
abstract
Results from a potable water microfiltration (MF) pilot study employing untreated surface water are reported. The effects of filtrate flux and recovery on direct flow, outside-inside, hollow fiber MF fouling rates, and backwash effectiveness are presented. Constant flux experiments suggested the existence of a critical recovery below which MF fouling rates were low and effectiveness of backwashes was high and relatively independent of the recovery. However, in the range of experimental conditions investigated, fouling rates increased dramatically and backwash effectiveness decreased steeply when this critical recovery was exceeded regardless of the flux. In general, for a fixed recovery, specific flux profiles analyzed on the basis of volume filtered per unit membrane area were insensitive to filtrate flux. Fouling was accelerated by operating membranes at constant flux rather than at constant pressure, in part, because of membrane compaction and cake compression. Changing the mode of filtration between constant flux and constant pressure is shown to have no effect on MF filtrate water quality. For any given capacity, membrane area requirements are decreased, and power requirements are increased when membranes are operated at constant flux rather than at constant pressure.