Evaluations of two methods to clean utility line: PWM-voltage source rectifiers and active power filters Conference Paper uri icon

abstract

  • Two methods to solve harmonic pollution problems caused by the diode rectifier are possible: one replacing the diode rectifier with a PWM rectifier and the other connecting an active power filter to the diode rectifier. Despite numerous publications for two converters, the features and evaluations between them have not been clearly explained. This paper, in detail, presents a theoretical analysis and a systematic comparison of the two converters, from the point of view of converter kVA ratings, dc bus voltage requirements, switch ratings, and reactive component designs.

name of conference

  • 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551)

published proceedings

  • PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS

author list (cited authors)

  • Kwak, S., Toliyat, H. A., & Fahimi, B.

citation count

  • 3

complete list of authors

  • Kwak, S||Toliyat, HA||Fahimi, B

publication date

  • January 2004