A 60-dB dynamic-range CMOS sixth-order 2.4-Hz low-pass filter for medical applications Academic Article uri icon

abstract

  • The design and implementation of a fully integrated complementary metal-oxide-semiconductor (CMOS) sixth-order 2.4 Hz low-pass filter (LPF) for medical applications is presented. For the implementation of large-time constants both linearized operational transconductance amplifiers with reduced transconductance and impedance sealers schemes for grounded capacitors are employed. Experimental results for the filter have shown a dynamic range (DR) of 60 dB, while the harmonic distortion components are below -50 dB. The power consumption for the filter is below 10 //W, the power supply is 1.5 V, and the active area is 1 mm2. The filter was fabricated in a double poly double metal 0.8 m CMOS process. 2000 IEEE.

published proceedings

  • IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-ANALOG AND DIGITAL SIGNAL PROCESSING

altmetric score

  • 3

author list (cited authors)

  • Solis-Bustos, S., Silva-Martinez, J., Maloberti, F., & Sanchez-Sinencio, E.

citation count

  • 183

complete list of authors

  • Solis-Bustos, S||Silva-Martinez, J||Maloberti, F||Sanchez-Sinencio, E

publication date

  • January 2000