Assessment of the role of slit as a safety valve in failure of levees Academic Article uri icon

abstract

  • The development of a narrow channel or slit due to piping just underneath the base of levees channel has been reported to be useful to withstand the increase in the head beyond critical head conditions. Also, the maximum slit length has been emphasized to be up to half of the base width. By developing a model of critical head considering slit, it is found that the critical head can increase with the development of slit length only under certain conditions. Analysis of piping failure data indicates that the critical head expressions considering slit length constitute a potentially useful model for critical head. 2008 International Research and Training Centre on Erosion and Sedimentation and the World Association for Sedimentation and Erosion Research.

published proceedings

  • INTERNATIONAL JOURNAL OF SEDIMENT RESEARCH

author list (cited authors)

  • Ojha, C., Singh, V. P., & Adrian, D. D.

citation count

  • 7

publication date

  • December 2008