AC/DC adapters mostly employ two-stage topology: Power Factor Correction (PFC) pre-regulation stage followed by an isolated DC/DC converter stage. Low power AC/DC adapters require a small size to be competitive. Among their components, the bulk DC-link capacitor is one of the largest because it should keep the output voltage with low ripple. Also, the size of this capacitor is penalized due to the universal line voltage application. Synchronization through employing leading edge modulation for the first PFC stage and trailing edge modulation for the second DC/DC converter stage can significantly reduce the ripple current and ripple voltage of the DC-link capacitor. Thus, a smaller DC-link capacitance can be used, lowering the cost and size of the AC/DC adapter. Benefits of the synchronous switching scheme were already demonstrated experimentally. However, no mathematical analysis was presented. In this thesis, detailed mathematical analyses in per-unit quantity are given to facilitate the calculation of the DC-link capacitor ripple current reduction with Leading/Trailing Edge Modulation strategies. One of the limitations of leading/trailing edge modulation is that the switching frequencies of the two stages need to be equal to achieve the best reduction of the DC-link capacitor ripple current. The DC-link capacitor ripple current will become larger if the switching frequency of the DC/DC converter is larger than that of the PFC pre-regulator, which blocks us to employ higher frequency for isolated DC/DC converter to reduce its transformer size. This thesis proposed a new Leading/Trailing Edge Modulation strategy to further reduce the DC-link bulk capacitor ripple current when switching frequency of DC/DC converter stage is twice the switching frequency of PFC stage. This proposed pulse width modulation scheme was verified by simulation. Experimental results obtained through digital control based on FPGA are also presented in this thesis.